Reference Number NIA_CAD0038
Title Remote Live Mains Insertion (RLMI)
Status Completed
Energy Categories Fossil Fuels: Oil Gas and Coal(Oil and Gas, Refining, transport and storage of oil and gas) 100%;
Research Types Applied Research and Development 100%
Science and Technology Fields ENGINEERING AND TECHNOLOGY (Mechanical, Aeronautical and Manufacturing Engineering) 100%
UKERC Cross Cutting Characterisation Not Cross-cutting 100%
Principal Investigator Project Contact
No email address given
Cadent Gas
Award Type Network Innovation Allowance
Funding Source Ofgem
Start Date 01 April 2019
End Date 01 March 2021
Duration ENA months
Total Grant Value £235,000
Industrial Sectors Energy
Region London
Programme Network Innovation Allowance
 
Investigators Principal Investigator Project Contact , Cadent Gas (100.000%)
  Industrial Collaborator Project Contact , Cadent Gas (0.000%)
Web Site https://smarter.energynetworks.org/projects/NIA_CAD0038
Objectives RLMI will be designed for use from within an excavation and will permanently abandon the annular space between the existing metallic service and the new PE liner. The RLMI solution builds on several robust, approved and commercially available techniques offered by SVI, including GIS:LC14 approved Sealants and Foambag systems The scope has been developed and agreed between Cadent and SVI.1. In house testing Steve Vick International Ltd (SVI) will carry out testing on the two Tier 1 pipe diameters. In total there will be 9no. tests of 75mm PE in a 4” host mains & 9no. tests of 125mm PE pipe in 6” host mains. Host mains will include cast iron, ductile iron and steel. The tests will confirm positioning, foambag and annulus sealing performance, through associated pressure testing.2. Full system testingThis will test the systems ability to be deployed successfully and ability to cope with varying host pipe substrates. The tests will be performed at the SVI depot with a Cadent representative present to witness the testing. A total number of three full system tests will be carried out for each pipe diameter combination using varying host mains.3. Field trialsOnce laboratory testing has been completed successfully, a period of field trials under G23 guidance will be required. The field trials will be carried out on the Cadent network and be witnessed by the SVI project manager and representative(s) from Cadent. The installation will be performed by SVI technician teams. There shall be a minimum of 12 field trials, with six field trials for each pipe diameter size combination. The objective of the project is to test the RLMI method through the phases detailed in the project scope, above
Abstract RLMI will be designed for use from within an excavation and will permanently abandon the annular space between the existing metallic service and the new PE liner. The RLMI solution builds on several robust, approved and commercially available techniques offered by SVI, including GIS:LC14 approved Sealants and Foambag systems.